Parts you will receive:
1 - Ecofit Gateway
1 - USB to Serial Cable with Wireless Bridge Assembly
Contains:
1 - USB to Serial Cable
1 - Wireless Bridge
1 - Wireless Bridge Power Supply
1 - Wireless Bridge to T-Max Assembly with Radianse pass through
Contains:
1 - Serial cable
1 - Serial cable gender changer
1 - Wireless bridge
1 - Wireless bridge power supply
1 - Serial Splitter
A note about IT room installation:
Please ensure that the IT room is within approx. 100ft of the T-Max unit. If there are range concerns either install the Gateway at the front desk or contact Ecofit Support for alternate options.
Set Up:
In the IT Room:
1 - Set up the Gateway in the IT Room as per Gateway Set-up Instructions.
2 - Connect the USB to Serial Cable with Wireless Bridge assembly to the Gateway.
2.5 - Connect the Gateway Wireless Bridge to power outlet.
At the Front Desk:
1 - Disconnect the Radianse Serial Cable from the T-Max controller.
2 - Connect one end of the Serial Splitter to the Radianse Serial Cable.
3 - Connect one end of the serial cable to the Serial Splitter and the other end to the Serial port on the T-Max controller.
4 - Connect the paired Wireless Bridge to the final open spot on the serial splitter using the Serial Gender Changer.
4.5 - Connect the paired Wireless bridge to power outlet.